MPL 500 Series
switches offer pressure, vacuum, and differential
sensors, sensitive to as low as 0.05 in/H 2 O. Their
accuracy and reliability offer the designer an
excellent general purpose low pressure to electric
interface for monitoring and control applications.
Miniature size and low cost make the
500 Series ideal for OEM applications.
· View Schematic
MPL 500 is
diaphragm-operated
utilizing low stress deflecting contacts.
Elimination of sliding or pivoting parts results in
high reliability and long service life. Diaphragm
material can be selected for the operating medium,
temperature range, and other parameters. During the
development of a specification, actuation point can
be moderately adjusted by the designer. In
production, a factory setting is required.
MPL 500,
501,
502 and
503 are single-setting
models, available as pressure, vacuum or
differential pressure sensors. MPL 504
offers two settings. MPL 533 adds the
capability to switch high current loads, utilizing
an integral AC static switch (triac). No power
source is required other than the AC load.
Body:
glass-filled polyester, grade SEO, standard
Diaphragm: polyurethane,
fluorosilicone, EPDM, Teflon, and other materials
are available Terminals:
brass, gold-plated
Contacts: phosphor bronze with gold
inlay standard. Other materials available Operating
Temperature: -40 to +120C (-40 to +250F),
depending on components. Consult factory.
Operating Pressure: 0.05 in/H 2 O to
550 in/H 2 O (20psi)
Burst: 25 psi
Response: MPL 500/501/503/504/533,
160Hz; MPL 502/528/509, 270Hz
Life: Over 100,000,000 cycles Form:
SPST-NO, SPST-NC, 2x, SPST-NO (Form F) MPL 504
Resistance: 500 milliohm maximum
Weight: 10 grams
MPL 500 switches are designed
for low current and logic applications, such as LED
indicators and solid state relays. Typically, a load
of 10 to 20mA will ensure reliable switching. For
inductive loads, a varistor or R-C snubber circuit
is recommended. To switch heavier loads,
use any MPL 500 Series switch with an
interface device such as solid state relay (or
select the
MPL 600 or
9300 Series). Ask your MPL application
engineer about using the MPL 500 with an AC
static switch for loads up to 5A. The
MPL 533 features an integral triac. Current
capacity of the MPL 533 is limited by duty
cycle (% on-time) and ambient temperature. However,
source voltages from 6 to 240VAC can be used with
long life and high reliability.
Finally, for loads up to 25A, see the
MPL 600 Series.
NEMA 0.020" x 0.187" male tabs are
standard, for female quick disconnects. Low-profile
terminals for 18-22 gage wire are recommended.
Optional bifurcated terminals are also available on
all models, which will accept 0.020" x 0.187" or
0.020" x 0.110" female quick disconnects.
Terminals are available for printed circuit board
mounting. Custom applications requiring elongated
terminals, tinning, and custom wiring can also be
accommodated.
The standard polyurethane
diaphragm functions as both sensor and seal. For
dynamic applications such as fan monitoring, the
diaphragm alone provides an adequate seal. In static
applications (leak detection, liquid level, etc.) a
secondary internal gasket will ensure an almost
bubble tight seal of the pressure cavity.
All MPL 500 Series
sensors are available with factory settings from
0.05 to 550 in/H 2 O. Tolerance is typically about
10% of the setpoint. Ask your MPL application
engineer for more information on tolerances.
Range A 0.05 to
0.75 in/H 2 O Range B 0.50 to 3.00 in/H 2
O Range C 2.00 to 13.00 in/H 2 O
Range D 10.00 to 50.00 in/H 2 O
Range E 25.00 to 200.00 in/H 2 O
Range F 100.00 to 550.00 in/H 2 O
The MPL 508 adds a
1/8" brass fitting to the MPL 502 features.
MPL 509 adds a 5/32" barbed brass fit-ting,
and a 5/16" nut and washer for panel mounting.
1/8" NPT Port (above, left) can be molded
or die-cast. 5/32" barbed brass port (above, right)
also has 5/16" nut and washer for panel mounting.
|
|
|