The DaqPRO™ is a portable,
battery operated data acquisition and logging system
offering 16-bits, high-resolution, 8 channel data logging.
The DaqPRO™ features powerful graphical display and
analysis functions for measuring voltage, current and
temperature. It is designed to provide a professional,
compact, stand-alone low cost data logging system for a wide
variety of applications.
|
| |
System benefits include:
- High-end data acquisition
hand-held mobile solution
- 8 channels each capable of
measuring seven popular parameters
- Setup on every port makes it
viable for all industries
- Stand-alone operation:
Display and keyboard for field programming and analysis
(graph/table)
- Rechargeable 7.2V battery
with over 500 charging cycles
- High sampling rate – up to
4,000 samples/second
- Large data storage 512 KB
RAM
- Fast communication channels:
USB
- Multiple logging storage of
up to 100 sampling sessions
- Scales readings into
meaningful engineering units e.g. bar, ppm
- Built-in clock and calendar
keeps track of time and date for each data recording
- On screen text editing to
annotate collected data
Truly Independent Data
Acquisition in the Field
DaqPRO™ is battery operated and
is capable of sampling, processing and displaying measurements
without connecting to a computer. Designed to serve the needs of
professional data loggers, DaqPRO™ is a professional,
cost-effective, compact and stand-alone data logging system that
can be used with a wide variety of applications. This 16-bit,
high-resolution, eight-channel data logger offers the pros
graphic displays and analysis functions for measuring voltage,
current and temperature in real-time.
Accessories
- Carrying case
- NTC temperature probe
- Solar cell and battery for
field data logging
- Weather box complies with
the IP-67 standard for protecting DaqPRO™ while working in
field applications
DaqPRO™ 5300 8-Input Channels
Measure
0 – 24 mA
- Range 0 to 24 mA
- Resolution 0.47 µA
- Accuracy ±0.5%
- Loop impedance - 21Ω
0 – 50 mV
- Range 0 to 50 mV
- Resolution 3 µV
- Accuracy ±0.5%
0 – 10 V
- Range 0 to 10 V
- Resolution 200 µV
- Accuracy ±0.5%
- Loop impedance - 125 KΩ
Temperature NTC
- NTC – 10/100KΩ resistor
- Range -25 to 150 ºC
- Resolution 0.05 ºC
- Accuracy 0.5%
Temperature PT-100
- Range -200 to 400 ºC
- Resolution 0.1 ºC (7 mΩ)
- Accuracy:
-200 to -50 ±0.5 %
50 to 400 ±0.5 %
-50 to 50 ±0.5 ºC
The DaqPRO™ offers up to 8 PT-100 2
wire channels or 4 PT-100 3 wire channels
Temperature Thermocouple J
- Range -200 to 1,200 ºC
- Resolution 0.1ºC (1 µV)
- Accuracy:
-200 to -50 ±0.5%
50 to 1,200 ±0.5%
-50 to 50 ±0.5ºC
- Cold junction compensation
error: ±0.3 ºC
Temperature Thermocouple K
- Range -250 to 1200 ºC
- Resolution 0.1ºC (1 µV)
- Accuracy:
-250 to -50 ±0.5%
50 to 1,200 ±0.5%
-50 to 50 ±0.5ºC
- Cold junction compensation
error ±0.3 ºC
Temperature Thermocouple T
- Range -200 to 400 ºC
- Resolution 0.1 ºC (1 µV)
- Accuracy:
-200 to -50 ±0.5%
50 to 400 ±0.5%
-50 to 50 ±0.5ºC
- Cold junction compensation
error ±0.3 ºC
Internal Temperature
- Range -25 to 70 ºC
- Resolution 0.1ºC (1μV)
- Accuracy ±0.3ºC
Pulse Counter (Input 1 only)
- Optocoupler input
Range: 0-65,000
- Input signal: 0-5 V
- Input impedance: 470Ω
- Bandwidth: 0-25 Hz
Frequency Meter (Input 1
only)
- Optocoupler input Range:
20-4,000 Hz
- Input signal: 0-5 V
- Input impedance: 470Ω
|